PES(G)11-250AI Outdoor Communication Cabinet
PES(G)11-450 Outdoor Communication Cabinet
1.The Cabinet meet YD/T1313-2004
2.The MDF modle meet YD/T694-2004
PES(G)11-450 Outdoor Communication Cabinet
Summary
Meet the "China Telecom outdoor cabinets technical specifications "and YD/T1313-2004"broadband data communications distribution cabinet" and the relevant requirements.
Feature:
1.work circumstance
Operating temperature: -40 ~ +65 (degree) Storage temperature: -40 ~ +70 (degree)
Temperature: -45 ~ 70 (degrees) Relative Humidity: ≤ 90%
Atmospheric pressure: 62kap ~ 106kpa
Electromagnetic interference: field strength ≤ 140dB V / m, the frequency range of 0.01 MHZ ~ 110000MHZ
Fan control: 35 degrees start, 27 degrees to stop
2.Characteristics:
1. Cabinet with 1.5mm cold rolled steel, steel hot-dip galvanizing process, zinc-plating meet GB/T13912-1992 requirements. Surface using spray treatment. Cabinet lock with three locking structure, anti-damage performance meet GA / T 73-1994 in the B-class requirements.
2. Cabinet as a whole has a dust-proof, waterproof, fog proof, pest control properties. Protection grade IP65. Inlet and outlet with reusable seals for waterproof cabinet. Fire cabinet rank higher than two. Materials used are fire retardant material.
3. Noise performance: closed state, the distance of 1.5m enclosure, the maximum noise meet the following requirements:
a. 1: residential area, less than 55dB
b. 2: other regions, less than 76dB
4. Grounding protection: the protection of ground equipment cabinets connected to the row of ground pool
Main device capacity :2 sets for Huawei MA5616(EPON) OR ZTE 9806H(EPON)